Daltonen
電子向け超純水ソリューション

Industry Solution

電子向け超純水

Semiconductor, panel and photovoltaic manufacturing have very high requirements for ultrapure-water resistivity, TOC and particles.

Recommended Membranes
PURE Brackish Water RO Series
MATE100 Nanofiltration Series
ULTRA Ultrafiltration Series

Solution Brief

Define the membrane solution from operating conditions

  Back to Solutions
01

Industry Challenges

Extremely low TOC, high resistivity, strict particle control and stable product-water consistency.

02

Solution Design

RO+NF+UF multi-stage membrane separation removes salts, organics and particles step by step, providing stable pretreated water for final polishing.

03

Recommended Configuration

PURE Brackish Water RO SeriesMATE100 Nanofiltration SeriesULTRA Ultrafiltration Series

Process Design

電子向け超純水Recommended Process

From raw-water pretreatment to product-water reuse and concentrate handling, this forms a complete technical route for further review.

UF
01 · Pretreatment

Multimedia filtration / UF

Remove suspended solids, colloids and microorganisms to protect downstream desalination.

Output: 稳定低浊进水
NF
02 · 硬度管理

Softening / NF and fine filtration

Reduce hardness, alkalinity and scaling tendency to support higher recovery.

Output: 降低结垢风险
RO
03 · 一次脱塩

First-pass RO

Remove most dissolved salts, silica and organics to produce pre-desalinated water.

Output: 低 TDS 产水
RO
04 · 高度脱塩

Second-pass RO / EDI

Further reduce ionic loading to provide stable feedwater for ultrapure water polishing.

Output: 高純水基水
UV
05 · 最終ポリッシング

UV, mixed-bed resin and final UF

Control trace ions, TOC and particles to meet production requirements.

Output: 超純水
06
06 · 循環給水

Storage and distribution loop

Maintain stable water quality through continuous recirculation and point-of-use monitoring.

Output: 稳定到达用水点
Feed Side
Industrial Raw Water
Product Water Side
Electronics-grade Ultrapure Water
Concentrate / By-product
RO Concentrate / Regeneration Wastewater
Engineering Note

Specify ultrapure water polishing for the resistivity, TOC, boron, silica and particle requirements of the wafer, display or photovoltaic production line.

Need to further confirm solution boundaries?

Provide feed-water quality, capacity and product-water targets to get selection advice for the current project.

Contact Technical Team