Declining UF permeate flow, rising transmembrane pressure and more frequent backwashing do not necessarily mean that a membrane element has failed. A mismatch between feedwater fouling load, membrane configuration, design flux and cleaning strategy can reduce system performance. Hollow-fiber UF and tubular UF (TMF) are both pressure-driven separation processes, but their flow channels and operating limits differ. Using the DALTONEN® product portfolio as a reference, this article explains feedwater quality control and engineering selection.
01 How UF Works: Why Feedwater Quality Determines Operating Stability
Ultrafiltration primarily uses pore-size exclusion to retain suspended particles, colloids, bacteria and some macromolecular organics. Virus retention depends on pore size, membrane integrity and validation. Conventional UF generally cannot effectively remove dissolved salts or small organic molecules. During filtration, particle deposition, pore blockage, organic adsorption and biofilm formation can increase resistance, causing transmembrane pressure (TMP) to rise at constant flow or permeate flux to decline at constant pressure.
02 Hollow-Fiber or Tubular Ultrafiltration: What Is the Difference?
Hollow-Fiber UF: Water Purification and RO Pretreatment
Hollow-fiber membranes offer high packing density and suit surface-water purification, desalination pretreatment, industrial pure water and reclaimed-water treatment. Depending on the module, filtration may be inside-out or outside-in, dead-end or crossflow. DALTONEN DA-ULTRA-400, DA-ULTRA-4040 and DA-ULTRA-550 are representative models; specifications and permitted conditions must follow the relevant technical datasheet.
Tubular UF: Complex Wastewater and High-Solids Process Streams
DA-TMF tubular membranes have wider flow channels and typically operate in crossflow, using recirculation to reduce surface deposition. Applications include juice clarification, fermentation-broth filtration, biologically treated landfill leachate and industrial wastewater with high suspended solids. Selection should assess solids content, particle size, viscosity, crossflow velocity, piping pressure loss and cleaning conditions. Wider channels do not eliminate fouling risk, and recirculation-pump energy must be included in the economic assessment.
| Comparison | Hollow-Fiber UF | Tubular TMF |
|---|---|---|
| Configuration | High packing density; compact construction | Wider channels suited to crossflow |
| Typical Feedwater | Surface water, pretreated wastewater and seawater | High-solids wastewater and complex process fluids |
| Operating Priorities | Backwashing, integrity and TMP | Crossflow velocity, viscosity and pressure loss |
| Energy Considerations | Usually lower; dependent on operating mode | Recirculation-pump energy requires particular attention |
03 UF Feedwater Quality: Which Parameters Matter in Engineering Design?
There is no single set of feedwater limits suitable for every UF or TMF module. Establish design and alarm values using source-water variability, membrane material, channel geometry, pretreatment configuration and the manufacturer's permitted operating range.
| Parameter | Control and Assessment | Engineering Significance |
|---|---|---|
| Turbidity (NTU), TSS (mg/L) | Monitor normal and peak values; set limits for the selected module | Assess particle deposition and backwash loading |
| SDI₁₅ | Primarily assesses particulate fouling potential when UF permeate feeds RO; an optimization target below 3 is common, subject to RO requirements | Not a mandatory threshold for every UF feedwater |
| TOC、DOC、COD(mg/L) | Assess organic composition together with actual filtration tests | Evaluate adsorption, organic fouling and biofouling risks |
| UV254、SUVA | Provides supporting information on organic characteristics; SUVA is normalized by DOC | Cannot independently identify a fouling source or determine a cleaning interval |
| Iron and Manganese (mg/L) | Distinguish dissolved and particulate forms; use oxidation and filtration where needed | Prevent deposition and pore blockage |
| Hardness and Alkalinity | Evaluate with pH, temperature and saturation conditions | UF does not directly remove dissolved hardness |
| Oils and Hydrocarbons | Select pretreatment according to oil form and membrane compatibility | Reduce adsorption and irreversible fouling |
| pH, Temperature and Oxidants | Remain within the selected model's operating and cleaning limits | Avoid damage to membrane materials and seals |
| Viscosity, Solids Content and Maximum Particle Size | Prioritize crossflow trials for complex process fluids | Affect TMF flux, pressure loss and recirculation-pump selection |
This table provides engineering guidance, not guaranteed limits for all DALTONEN models. It replaces the original attached water-quality table to avoid presenting particular low-fouling water targets as universal UF feedwater restrictions.
04 Declining UF Flux and Rising TMP: How to Troubleshoot
First distinguish membrane fouling from temperature changes, instrumentation problems and changing hydraulic conditions. Record feed, permeate and concentrate pressures; inlet and outlet flows; temperature; turbidity; and performance before and after cleaning.
Membrane Flux J = 1000Q/A, where Q is permeate flow (m³/h), A is effective membrane area (m²), and J is expressed in LMH. For crossflow systems with feed and concentrate pressure measurements, a common expression is TMP = (Pfeed + Pconcentrate)/2 − Ppermeate. For dead-end filtration, calculate TMP using the actual measurement points and membrane manufacturer's definition; piping inlet-to-outlet pressure loss is not automatically equivalent to TMP.
| Operating Symptom | Possible Causes | First Checks |
|---|---|---|
| Continuously Rising TMP | Cake deposition, organic fouling or scaling | Check feed loading, backwash effectiveness and temperature |
| Declining flow without a significant pressure change | Low temperature, insufficient supply, valve or instrument faults | Check pumps, valves, flowmeters and temperature correction |
| Limited flux recovery after backwashing | Adsorption, pore blockage or irreversible fouling | Analyze foulants and develop a chemically compatible cleaning procedure |
| Abnormally High Permeate Turbidity | Fiber damage, failed seals or bypass flow | Perform integrity testing and inspect piping |
05 UF System Design and Operation
A typical hollow-fiber UF system includes pretreatment, a feed pump, membrane modules, a permeate tank, backwashing and chemical cleaning. Filtration, backwashing, air scouring where applicable, forward flushing and return-to-service sequences depend on the module. Chemically enhanced backwashing (CEB) and clean-in-place (CIP) procedures must reflect membrane compatibility and actual fouling; do not copy chemical concentrations or cleaning intervals from another model.
At the design stage, calculate net permeate production after backwash consumption, discharge and downtime. During operation, track temperature-corrected flux and TMP trends. For tubular membranes, pay particular attention to recirculation flow, pressure loss, concentration factor and changes in fluid viscosity.
06 Selecting DALTONEN Ultrafiltration Membranes
DALTONEN Membrane Technology (Shenzhen) Co., Ltd. supplies DA-ULTRA hollow-fiber and DA-TMF tubular ultrafiltration membranes. For conventional water purification and RO pretreatment, evaluate hollow-fiber systems first. For juice clarification, concentrated wastewater or complex process fluids, evaluate tubular crossflow systems. Final selection requires feedwater analysis, treatment capacity, target permeate or concentration specifications and pilot results where necessary.
07 Frequently Asked Questions
Can UF Reduce TDS and Hardness?
Conventional UF primarily retains particles and macromolecules; it does not effectively remove dissolved salts or hardness. Evaluate RO, NF or other processes when desalination or softening is required.
Is Lower UF Feedwater Turbidity Always Better?
Reducing particulate loading generally helps operation, but also increases pretreatment cost. Set practical control targets around the membrane type, contaminant characteristics and water-quality variability.
How Often Should UF Membranes Be Cleaned?
There is no universal interval. Follow the manufacturer's requirements and assess TMP changes, temperature-corrected flux and backwash recovery.
Can Tubular Membranes Directly Treat Every Concentrated Wastewater?
No. Confirm particle size, oil content, viscosity, solids content, chemical compatibility and recirculation conditions. Pretreatment and pilot testing may be necessary.
08 Technical References and Standards
HG/T 5111-2025, Column-Type Hollow-Fiber Membrane Modules, took effect in March 2026. It covers research, manufacture and inspection of the relevant column-type microfiltration and ultrafiltration modules; it does not establish universal feedwater limits for all UF systems.
National Public Service Platform for Standards Information: HG/T 5111-2025;Reference for UF Feedwater Design Parameters;Research on SUVA and Dissolved Organic Carbon Aromaticity. External manufacturers' materials are references for general technical methods only, not DALTONEN product specifications.